Electrolyser whole system Test 05.07.2022

00002: WHOLE SYSTEME TEST

 Step

 Step Description

 Expected Result

 Result

 Precondition

 System is off

 

 

 Open the valves V1 and V2  

 Open the valves V1 and V2 from the GUI

 The valve V1 and V2 are open and enable to let the nitrogen gas pass

 Positive

 WASH THE SYSTEM WITH NITROGEN

 Wash the system with Nitrogen for few minutes BY TURNING ON THE VALVE on the nitrogen tank  

 One can see that there is nitrogen exit from the gas outlets

 Positive

 Switch on the system

 Turn off the nitrogen

 Turn on the system from the GUI 

 THE SYSTEM IS GENERATING hydrogen and oxygen

 Positive

 Burn the hydrogen

 Turn on the transformator

 The Hydrogen is burning

 Negative

 Switch off the system

 Switch off the system from the GUI

Switch off the transformator 

 The system goes down

 Positive

 WASH THE SYSTEM WITH NITROGEN

 Wash the system with Nitrogen for few minutes BY TURNING ON THE VALVE on the nitrogen tank 

 All the hydrogen existing in the pipe system exit

 Positive

 Postcondition

 System is off

 

 

After correcting the KOH concentration, we started the test and successfully generated hydrogen.
However, the quantity was very low, so ignition did not occur.

 

Test analysis :

It can be 2 Reason for the low generated quantity :

1- Either the concentration is yet too low knowing that we rise it .

2- Or the current passing through the cells is too low .

or the two reasons together .

 

what we have to do :

Do a test with the maximum possible concentration  of the KOH. If this is not successful we have to define which power supply should be used instead . this is done by installing measuring instruments to detecct the voltage and the current passing through the cells .