Electrolyser whole system Test 05.07.2022
00002: WHOLE SYSTEME TEST
Step |
Step Description |
Expected Result |
Result |
Precondition |
System is off |
|
|
Open the valves V1 and V2 |
Open the valves V1 and V2 from the GUI |
The valve V1 and V2 are open and enable to let the nitrogen gas pass |
Positive |
WASH THE SYSTEM WITH NITROGEN |
Wash the system with Nitrogen for few minutes BY TURNING ON THE VALVE on the nitrogen tank |
One can see that there is nitrogen exit from the gas outlets |
Positive |
Switch on the system |
Turn off the nitrogen Turn on the system from the GUI |
THE SYSTEM IS GENERATING hydrogen and oxygen |
Positive |
Burn the hydrogen |
Turn on the transformator |
The Hydrogen is burning |
Negative |
Switch off the system |
Switch off the system from the GUI Switch off the transformator |
The system goes down |
Positive |
WASH THE SYSTEM WITH NITROGEN |
Wash the system with Nitrogen for few minutes BY TURNING ON THE VALVE on the nitrogen tank |
All the hydrogen existing in the pipe system exit |
Positive |
Postcondition |
System is off |
|
After correcting the KOH concentration, we started the test and successfully generated hydrogen.
However, the quantity was very low, so ignition did not occur.
Test analysis :
It can be 2 Reason for the low generated quantity :
1- Either the concentration is yet too low knowing that we rise it .
2- Or the current passing through the cells is too low .
or the two reasons together .
what we have to do :
Do a test with the maximum possible concentration of the KOH. If this is not successful we have to define which power supply should be used instead . this is done by installing measuring instruments to detecct the voltage and the current passing through the cells .